Why the Digital Switchover Will Disrupt Your Lift’s Emergency Communication — And What You Need to Do
The UK’s telecommunications network is undergoing its biggest transformation in decades. By the end of 2025, the traditional analogue copper lines that have carried phone calls for over a century — known as the Public Switched Telephone Network (PSTN) — will be permanently switched off.
This shift to all-digital networks, utilising VoIP (Voice over Internet Protocol), GSM (mobile), or IP-based systems, will impact more than just home phones and fax machines. It has serious implications for safety-critical services — including the emergency communication systems installed in lifts.
For building owners and facilities managers, understanding the impact of the digital switchover is not optional. If your lift’s emergency call system relies on the old network, it may soon fail — putting both compliance and passenger safety at risk.
Why Lifts Are Affected
Most passenger, goods, and platform lifts are fitted with an auto-dialler. This is a vital safety feature: in the event of someone becoming trapped, pressing the alarm button connects them to a 24-hour emergency centre.
Traditionally, these auto-diallers have been connected to the PSTN via a standard analogue line. This worked reliably for years, with a key benefit: the copper line itself carried power, meaning that even in a building-wide power cut, calls could still be placed without the need for complex backup arrangements.
With the transition to digital networks, that advantage disappears. VoIP and GSM connections do not supply their own power. Unless both the auto-dialler and its communication device (such as a GSM gateway) have adequate battery backup, the system may be unable to make an emergency call in a power outage.
The PSTN Switch-Off Timeline
The switch-off is already in progress. Telecom providers are gradually decommissioning analogue and ISDN lines, with some areas moving faster than others, depending on local exchanges.
Originally, the UK’s Digital Switchover was due for completion by December 2025. However, the deadline has now been extended to 2027 in some areas. While this provides extra breathing room, it does not mean building owners can afford to delay. Analogue services are still being withdrawn region by region, meaning some sites will lose PSTN connections long before 2027.
In practice, any lift still relying on analogue risks being left without a functioning emergency communication system well before the final national cut-off.
How the Digital Switchover Affects Lift Auto-Diallers
Once the PSTN is removed, any auto-dialler that relies on an analogue line may stop working entirely. Even where interim solutions such as analogue telephone adaptors (ATAs) are used to “bridge” old systems onto digital networks, these are only temporary measures and may become obsolete as networks evolve.
Other key challenges include:
- Three-day test calls: Lifts must make an automatic test call every 72 hours. Under the new requirements, this test must use the same method as a real emergency alarm call. Systems that previously used SMS for testing will no longer comply.
- Battery backup: Because digital and GSM systems do not carry their own power, both the auto-dialler and the network device need a monitored, compliant battery backup.
- Signal reliability: For GSM systems, issues such as SIM card credit, roaming vs single-network capability, and mobile coverage inside lift shafts and machine rooms become crucial.
- Futureproofing: Selecting a GSM or IP-based system with remote monitoring and multi-network SIM support helps mitigate the risk of failure.
The 2025 Updates to BS EN 81-28
The safety standards covering lift emergency communications have also been updated in line with the digital switchover. Two important changes in BS EN 81-28:2025 are:
- Three-Day Test Must Replicate Real Alarm Method
Any test call must now use the same pathway as a real emergency call. If the lift uses GSM voice for emergencies, the test must also use GSM voice — not SMS or another method. - Battery Backup Requirements
Both the auto-dialler and the communication interface (such as the GSM gateway or VoIP terminal) must have a monitored battery backup capable of functioning during power failures.
These updates are designed to ensure that lift alarm systems remain reliable and compliant in the digital era.
What Lift Owners and Managers Must Do Now
If you are responsible for a lift, you cannot afford to wait until the end of 2025. Some networks are already switching off analogue lines, and lifts left unmodified could quickly become non-compliant. The essential steps are:
- Audit your lift systems: Identify whether your auto-diallers are still running on PSTN or ISDN connections.
- Review your three-day test method to ensure it accurately mirrors the actual alarm call path.
- Check battery arrangements: Both the auto-dialler and the GSM/VoIP unit need reliable, monitored backup.
- Plan an upgrade: Retrofit a digital or GSM auto-dialler or consider replacing ancient systems entirely.
- Optimise connectivity: Use multi-network SIMs, ensure coverage in lift shafts, and consider remote monitoring for reliability.
- Engage a specialist: Work with a provider experienced in lift emergency communications, such as iKonic Lifts, to design and install a compliant solution.
Risks of Delay or Non-Compliance
Failing to act carries serious risks:
- Safety: Passengers could be trapped without the ability to call for help.
- Compliance: Lifts without functioning alarm systems may be taken out of service.
- Legal liability: Building owners may be held responsible for accidents or non-compliance.
- Insurance: Cover may be compromised if lifts do not meet updated standards.